product guide | ||||
|
||||
APPLICABLE Mil SPECIFICATIONS: FP series meet or exceed the electrical, mechanical environmental and dimensional requirements of Mil R-26. |
RESISTANCE TOLERANCE: ± 5% is standard on values above 1 ohm. ±10% is standard on 1 ohm and lower. 3%, 1%, .25% and .05% are also available. |
CORES: High purity ceramic impervious to moisture will withstand severe thermal shock. |
COATING: Special high-temperature silicone. |
DIELECTRICAL STRENGTH: 1000 VAC minimum for all FP series resistors. Available wound inductive or non-inductive. |
RESISTANCE WIRE: Highest quality copper-nickel-chrome alloy, depending on resistance value. |
SHORT TIME OVERLOAD: In intermittent usage the applied power can greatly exceed the wattage rating. However, since each pulse is somewhat unique the factory should be contacted for specific requirements. |
POWER RATING: Power rating is based on (1) 350° C maximum surface temperature in free air. (2) 3% maximum R in 2000 hour load life test. |
DERATING: FP types have an operating temperature range of -55° C to +350° C. They must be derated at high ambient temperature according to the curve shown below. |
M-O P/N | Core Length (A) ±.062 |
Hardware Length (B) ±.062 |
Mtg Hole Spacing (C) ±.015 |
Wattage Rating | Max. Working Voltage | Resistance Range (ohms) |
FP-10 | .750 | 1.250 | 1.00 | 10 | 300 | .1 - 15K |
FP-20 | 2.062 | 2.550 | 2.313 | 20 | 1000 | .1 - 51K |
For non-inductive types add letter N after part number. |
|
TO ORDER PRODUCT |
E mail: microohm@mail.com |
Call Toll Free: 1-800-845-5167 |
home page | product guide | R axial |
TL tubular lug | HS chassis mount | CW bathtub axial | SU bathtub printed circuit | PI radial |
EW edgewound |
RX vitreous axial |
CP bare axial |